SUBMERSIBLE CABLES


Q-FLX & WIRES & CABLES . Manufactures 3 core flat cables for use in submersible pump motors generally conforming to IS:694 - 1990, with annealed plain electrolytic grade high conductive copper conductor conforming to IS:8130 - 1984 and extruded with specially formulated
Q-FLX
brand PVC Compound for insulation and sheath to withstand any instantaneous surge voltage and current and impervious to water, grease, oil etc.


Identification of core colours:

No. of cores

  Identification

1

  Red or Black

2

  Red and Black

3

  Red, Yellow and Blue

4

  Red, Yellow, Blue and Black















The Cables are supplied in standard lengths of 500 mts ± 5%. However customer specified lenths also be supplied in wooden drums or in coils.



Normal Conductor Area

Number & Diameter
of
Wire

Nominal thickness
of Insulation

Nominal thickness
of
Sheath

Max. Overall Diameter

Max. Conductor Resistance at 20°C

Current Rating at
40°C

W

B

Sq.mm

No./mm

mm

mm

mm

mm

ohm/km

Amp.


1.5


2.5

4

6

10

16

25

35

50

70

95


22/0.3


36/0.3

56/0.3

85/0.3

140/0.3

126/0.4

201/0.4

273/0.4

325/0.45

440/0.45

485/0.5


0.8


0.9

1.0

1.0

1.0

1.0

1.2

1.2

1.4

1.4

1.6


1.15


1.15

1.15

1.15

1.40

1.40

2.00

2.00

2.20

2.20

2.40


12.5


14.4

17.2

18.7

23.7

28.0

35.5

39.5

45.5

51.0

60.0


5.8


6.3

7.4

7.9

9.9

11.4

14.7

16.2

18.3

20.0

23.5


12.1


7.41

4.95

3.30

1.91

1.21

0.780

0.554

0.386

0.272

0.206


16


22

29

37

51

64

75

90

115

143

165