FLRY – A (THICK WALL) CLASS B(T2)

MS Thin Wall Low Voltage Wires for Automobile (TYPE 1)
Application

Low-tension electric wire for Automobiles. Used in Motorcycles and other motor vehicIes for starting, charging, lighting, signal and instrument panel circuits. SuitabIe as fuel gange wire.

Technical Data
  • Standard: DIN 72551, Part 6, Type A and ISO 6722
  • Temperature range: – 40° C to +105° C (3000 Hours)
  • Conductor: Bright soft annealed electrolytic Copper E-Cu ETP1 according to DIN 13602, bare or tinned. construcfion according to DIN 72551, Part 6, type A and ISO 6722 . Conductor Resistance : I EC 60228 /BS 6360
  • Insulation: PVC with properties according to DIN 72551 and ISO 6722, Class B, Lead free.
  • Colours: As per customer requirement
  • Marking: Q-FLX Cable 0.5 SQ.MM FLRY A 105° C
  • Packing: Available in 100 meters coil, Longer coils on special packing available on request.
Product Features
Flame retardant.
Highly resistant against acids, lyes, Petrol and diesel.
FIexibIe conductors with thin wall Insulation for extra flexibility.
Technical Informtion
Area of ConductorNo. of Strands Max. Strand
Diameter 
Max. DC Conductor
Resistance at
20°C (ohm/km)
Minimum Insulation ThicknessMaximum Overall Diameter 
mm2mmmmPlain
Copper
Tinned
Copper
mmmm
0.50190.1937.138.20.602.30
0.75190.2424.725.40.602.50
1.0190.2718.519.10.602.70
1.25190.3014.915.90.602.95
1.50190.3312.713.00.603.0
2.0190.389.429.690.603.30
2.5370.287.607.820.703.60
3.0370.346.156.360.704.10
4.0370.384.714.850.804.40
5.0370.433.944.020.804.90
6.0370.253.143.230.805.0
8.0980.332.382.520.805.90
10.0630.461.821.851.06.50
12.01540.331.521.601.07.40
16.01050.461.161.181.08.30
20.02470.330.9550.9991.109.10
25.01540.460.7430.7571.3010.40