OUR PRODUCTS

    Download Brochure

    Multicore Round Cables

    Lead Free PVC Insulated Single Core Unsheathed Flexible CABLES Volatge grade Up to 1100 VOLTS IS 694:2010
    Application
    Suitable for wiring in machines, control panels, Electric power supplies etc under typical electrical installations for wiring in various electrical installations in dry and damp interiors.
    Technical Data
    • Approvals: IS 694 marked, FIA/TAC
    • Voltage Grade: Up to and Including 1100V
    • Conductor: Bright annealed bare electrolytic grade Copper conductor as per IS 8130:2013.
    • Insulation:The insulation is PVC compound Type D of general purpose as per IS 5831
    Sheath: The sheath is of PVC compound Type ST3 in case of general purpose PVC.
    • Colour Code of Cores:
      • 2 core – Red and Black.
      • 3 core – Red, Black and Yellow-green/Red, yellow and blue.
      • 4 core – Red, yellow, blue and yellow-green/Red, Yellow, blue and black.
      • Note: Any other Colour up on specific request will be provided.
    • Sheath Colour: Black Any other colour as per customer requirement.
    • Packing: Standard Packing : Supplied in 100 Meter Coil Polythene Wrapping & Also available 300mtr, 500mtr & 1000mtr on non returnable Wooden Drum on request. Longer lengths available on request
    • Marking : The cables are printed with marking of “Q-FLX Cables (Size) Sq.mm x (Core) YY 1100V IS 694 ISLCM/L-1115123”
    Product Features
    101 % Copper Conductivity, (IACS)  Extra Annealing
    100% Bunched Copper  Longer Service Life
    Product Variants Availble
    PRODUCT TYPESPECIFICATION
    Normal PVC 70°CIS 694, IS 8130 :2013 Class 5 ,IS 5831 TYPE D Insulation & ST-3 Sheath
    HR PVC 85°CIS 694, IS 8130 :2013 Class 5 ,IS 5831 TYPE C Insulation & ST-2 Sheath
    FR PVC 70°CIS 694, IS 8130 :2013 Class 5 ,IS 5831 TYPE D Insulation + ST-3 (FR) Sheath
    HR PVC 85°C + FRIS 694, IS 8130 :2013 Class 5 ,IS 5831 TYPE C Insulation + ST-2 (FR) Sheath
    FR-LSHIS 694 IS 8130 :2013 Class 5 ,IS 5831 TYPE D Insulation + ST-3 (FR-LSH) Sheath
     
    Technical Specification for PVC Insulated and PVC Sheathed Flexible Cables (Circular) with Copper conductor for working voltages up to and including 1100V
    Nominal Area of
    Conductor
    Number and
    Nominal Diameter
    of Wire
    Nominal Thickness
    of insulation
    Nominal Sheathing
    Wall Thickness
    Overall Dimension,
    Maximum
    Conductor
    Resistance
    at 20°C
    (Maximum)
       Single CoreTwo CoreThree CoreFour CoreFive CoreSingle CoreTwo CoreThree CoreFour CoreFive Core 
    mm2mmmmmmmmmmmmmmmmmmmmmmmmOhm/km
    0.516 /0.200.60.90.90.90.90.94.36.97.38.08.739.00
    0.7524 /0.200.60.90.90.90.90.94.57.37.78.49.226.00
    132 /0.200.60.90.90.90.91.04.77.68.18.89.619.50
    1.530 /0.250.60.90.90.91.01.05.48.99.410.411.413.30
    2.550 /0.250.71.01.01.01.01.06.210.310.912.013.27.98
    456 /0.300.81.01.01.01.01.16.811.612.413.615.34.95
    684 /0.300.81.11.11.21.27.513.013.815.473.30
    1080 /0.401.01.31.31.41.49.416.517.6919.51.91
    16126 /0.401.01.41.41.41.410.919.420.623.01.21
    25196 /0.401.21.41.41.51.613.623.825.628.50.78
    35276 /0.401.21.61.61.61.715.527.229.332.70.554
    50396 /0.401.42.02.02.02.018.132.034.638.60.386
    **As per Class 5 Conductors of IS 8130:2013.Conforms to IS 694 : 2010.

    Note: The number and Diameter of the conductor strands are for reference only. The size of the conductor is determined by its resistance. it may vary within the limits of related Classes and tables of IS 8130:2013.
    The values given above are subject to tolrances as per relevent standards.